BREECH LOCK HEAT EXCHANGER PDF

High pressure screw plug (also called breech lock) exchangers are of the most reliable heat exchangers in the plant, it is very clear to me that. Threaded Closure Heat Exchangers. FBM-Hudson Italiana has developed design and manufacturing know-how to prevent hydrogen and high temperature . SCREW PLUG OR BREECH LOCK HEAT EXCHANGER (EASIER MAINTENANCE+SHORTER SHUTDOWN TIME = HIGHER EFFICIENCY) Presented by.

Author: JoJoramar Yozshusida
Country: Eritrea
Language: English (Spanish)
Genre: Travel
Published (Last): 14 October 2011
Pages: 352
PDF File Size: 20.21 Mb
ePub File Size: 17.80 Mb
ISBN: 499-4-52272-618-1
Downloads: 56640
Price: Free* [*Free Regsitration Required]
Uploader: Gule

Skip to main content. With the jig it is possible to open the channel, remove the internals, assemble and reclose of the Breech-Lock The exchangers in a very short time without need of heavy cranage.

After the catastrophic failure that occurred in a high-pressure Screw Plug enclosure in Japan and subsequent failures that were witnessed time and again in several parts of the world, this design screw plug lost its significance to a large extent. Log In Sign Up. Therefore this dilation, that is a cause of reduction in shear area, has to be restricted by using higher wall thickness in the threaded region. The internal bolts are used to apply the seating load to the gasket at the tubesheet and shell interface.

Designed and manufactured with the closest tolerances and highest attention to detail for reliability, easy maintenance and enhanced safety. The tubesheet for the Breech-Lock heat exchanger is designed for a differential pressure.

Breech Lock Heat Exchangers

Remember me on this computer. This higher wall thickness of the channel barrel immensely shoots up the cost of the forging. Detailed design has been improved and optimized over the years, even on minor details that can affect hreech and maintenance. The inner row of external bolts is used to increase the seating load between the tubesheet and shell gasket in the event of relaxation of the inner bolts. This resulted in bell mouthing in the threaded region thereby reducing the shear area of the threads, i.

TOP Related  ARIEL TOAFF PASQUE DI SANGUE PDF

Enter the email address you signed up with and we’ll email you a reset link. Heat ExchangersHome. This phenomenon can be logically understood and supported by calculations to show that the combined bending and longitudinal stresses breevh the undercut surface of the threads produce a wedging action that results in radial displacement, causing dilation of the channel. A special threaded ring hold the channel cover and contain channel pressure.

Screw Plug (Breech Lock) Heat Exchanger by TEMA INDIA – Haresh Sippy

This further resulted in expelling of the plug in an extreme circumstance, causing an explosion or jamming of the threads as was often experienced. A spreadsheet that will easily analyze the critical variables; 2. Dismantling and reassembling operations.

These exchangers are easy to operate and comparatively easy to dismantle and reassemble, which results in more reliable operation and shorter shut down time. Haresh Sippy, is just like a Fisherman who has to buy Fish! And finally hot exhcanger the exchangers after startup. It can be seen by analysis that the magnitude of bending stress can amount to three times the average longitudinal stress in the undercut area.

Some manufactures have given up on trying to make these exchangeer operate leak free, and prefer exchanegr weld in the tubesheets and diaphragms. Lower capital expenditure, easier maintenance, shorter shutdown time means higher plant reliability, lower total life-cycle cost.

TOP Related  ANSI A119.5 PDF

FEA analysis carried out at TEMA INDIA

After traveling around the world helping facilities turn these exchangers exchanyer chronic leakers from internal tubesheet and external diaphragm and B style shell leaks to one of the most reliable heat exchangers in the plant, it is very clear to that manufacturers, engineers and mechanics struggle to correctly understand the interactions between gaskets, internal pressure, the two circles of external push bolts that are part of A breecn exchangers and all the internal parts.

TEMA INDIA decided to conduct an extensive research program to bring about key changes to make this screw plug heat exchanger design totally safe and free of maintenance problems. Correct gasket selection; 3. The pressure load is absorbed by the threaded closure and the outer row of external bolts applies the seating load to the channel gasket. Help Center Find new research papers in: Excuanger Might Also Like. Click exchajger to sign up.

Correct assembly procedures that focus on important steps including proper spacing of internal parts and obtaining consistent thread friction; 4. This significantly adds to the cost and time needed to open and close these exchangers, as special equipment is needed to machine out the parts and weld them back together again.